Summary for Test 2024-07-28-3-11
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 993529 DEA: 11430514 EFIS: 1119000008 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-15-R31.3/R37.1 |
| Award Date | 05/27/2022 |
| Closeout Date | Not set |
| Work Description | CRCP, FIBER OPTIC CABLE, AND HMA. |
| Location Description | SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/07/2022) |
Sample Information
| Sample Taken Date | 07/28/2024 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/30/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
| The quantity of what the sample constitutes | 3 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | 6193804522 | |
| Laboratory sample identification | 6641-PSU | Linked DIME Sample ID | 2024-07-28-2 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-07-28-3
DIME Test ID: 2024-07-28-3-11
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-08-06
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 08/05/2024
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1920.5 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 491.7 grams | 74 % | |||||
| 670.5 grams | 65 % | |||||
| 1058.9 grams | 45 % | |||||
| 1349.0 grams | 30 % | |||||
| 1545.4 grams | 20 % | |||||
| 1669.0 grams | 13 % | |||||
| 1755.6 grams | 9 % | |||||
| 1813.5 grams | 6 % | |||||
| 1854.6 grams | 3.4 % | |||||
General comments (publicly viewable) (Max 1000 characters): HMA
Test was verified on 8/6/2024 ✔