Summary for Test 2017-07-07-4-18

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date07/07/2017 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing07/13/2017 Sample typeQuality Assurance
A brief description of the sample7/8 A325 Bolts, nuts and washers The quantity of what the sample constitutes402
From where was the sample collectedFabricator First name of sampler or witnessed byRussell
Last name of sampler or witnessed byLynch Title of samplerQAI
Telephone number of sampler(213) 538-8219 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameStinger Bridge Iron
Transportation Laboratory (TL) NumberC970157 Inspector Lot Number from the Transportation Laboratory (TL) FormL96-110-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0087693
Heat Number(s)10460750 Bolt 75065073 Nut B40551 Washer Nut Mfg. Lot Number(s)24877-75065073
Washer Mfg. Lot Number(s)1116-401 Bolt SpecificationA325
Bolt Length(s)2-1/4" Nut SpecificationA563
Washer SpecificationF436 FinishMechanically Galvanized
Diameter/Size7/8" Bolt Mfg. Lot NumberBM0500
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-07-07-4
DIME Test ID: 2017-07-07-4-18
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-07-27

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/19/2017
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 24877-75065073
Finish Coating: ASTM B695 - Mech Galv
Product Markings: U DH
Size: .875 in
Bolt Length: no data
Measurement Average: 5.31 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/20/2017 ✔