Summary for Test 2024-06-05-137-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993776
DEA: 040J3004
EFIS: 0413000433
DIST-CO-RTE-PM04-SON-1-26.7/27.1
Award Date07/08/2022
Closeout DateNot set
Work DescriptionCONSTRUCTING RETAINING WALL AND CONFINEMENT SYSTEM TO RESTORE SLIPOUT.
Location DescriptionSONOMA COUNTY NEAR JENNER FROM 0.3 MILE TO 0.7 MILE NORTH OF MEYERS GRADE ROAD
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date06/05/2024 Sample Unique Key137
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2024
Sample typeQuality Assurance A brief description of the sampleStructure Backfill
The quantity of what the sample constitutesApprox 250 cy From where was the sample collectedJob Site
First name of sampler or witnessed byCody Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identificationPET-24-214 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedSTA 20+00-24+00
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-06-05-137
DIME Test ID: 2024-06-05-137-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-07-31

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Cody Cordero
Date of test: 06/05/2024
Sum of Count or Density: 104035 g/cc
Average of Count or Density: 34678 g/cc
Sum of Moisture Count: 6648 g/cc
Average of Moisture Count: 2216 g/cc
Count Ratio Density: 1.05
Count Ratio Moisture: 0.24
Calculated Percent Relative Compaction: 91.3 %
Reported Percent Relative Compaction: 91 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/31/2024