Summary for Test 2024-07-22-33-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 994636
DEA: 022J9604
EFIS: 0221000153
DIST-CO-RTE-PM02-SIS-5-VAR
Award Date05/25/2023
Closeout DateNot set
Work DescriptionPLACE POLYESTER CONCRETE OVERLAY, HMA (TYPE A), & REPLACE JOINT SEALS.
Location DescriptionSISKIYOU COUNTY AT VARIOUS LOCATIONS FROM OAK STREET UNDERCROSSING TO KLAMATH RIVER BRIDGE AND SEPARATION BRIDGE NO. 02-0134R
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date07/22/2024 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2024
Sample typeVerification A brief description of the samplePSE
The quantity of what the sample constitutes2 CANS From where was the sample collectedSource
First name of sampler or witnessed byG Last name of sampler or witnessed byG
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero Benicia Transportation Laboratory (TL) Number858051
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-07-22-33
DIME Test ID: 2024-07-22-33-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-07-31

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 07/31/2024
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 51.177 kPa
Phase Angle (δ) (for the 10 cycles): 44.7 degree
Complex Modulus (G*) (for the 10 measurements): 5091.996 kPa
Test Temperature (Specimen 1): 16.0 C
(G*) x sin(δ)=: 3582 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 7/31/2024