Summary for Test 2024-07-20-3-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000035
DEA: 120T9804
EFIS: 1223000011
DIST-CO-RTE-PM12-ORA-22-R3.0
Award Date03/13/2024
Closeout Date06/08/2026
Work DescriptionREPAIR PAVEMENT AND UPGRADE GUARDRAIL.
Location DescriptionORANGE COUNTY IN WESTMINSTER AT WESTBOUND OFF-RAMP TO GARDEN GROVE BOULEVARD/KNOTT STREET
QA Service Level1 (Verified on 01/26/2024)

Sample Information

Sample Taken Date07/20/2024 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing07/21/2024 Sample typeQuality Assurance
A brief description of the sampleConcrete beams The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byRMA
Last name of sampler or witnessed byRMA Title of sampler
Telephone number of sampler Laboratory sample identification24-0335
Linked DIME Sample ID The fabricator/manufacturer/facility nameShort Load
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-07-20-3
DIME Test ID: 2024-07-20-3-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-07-30

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Dan Morris
Date of test: 07/30/2024
Identification number: 24-0335-1-3
Width of specimen: 5.9375 inch
Width of specimen 2: 6 inch
Width of specimen 3: 5.9375 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8100 lb
Maximum load applied 2: 8300 lb
Maximum load applied 3: 6940 lb
Curing history and apparent moisture condition of the specimen: Sand pit/Lime water bath (Contract Specs.)
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 700 psi
Modulus of rupture 2: 710 psi
Modulus of rupture 3: 600 psi
Modulus of rupture average: 670 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/30/2024 ✔