Summary for Test 2024-07-09-9-9

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994816
DEA: 010E11U4
EFIS: 0123000069
DIST-CO-RTE-PM01-MEN-1-31.1/31.6
Award Date11/15/2023
Closeout DateNot set
Work DescriptionSTRUCTURAL CONC BRIDGE, TEMP BRIDGE AND BAR REINFORCING STEEL.
Location DescriptionMENDOCINO COUNTY NEAR ELK FROM 0.2 MILE SOUTH OF ELK CREEK BRIDGE TO 0.2 MILE NORTH OF ELK CREEK BRIDGE
QA Service Level1 (Verified on 05/22/2023)

Sample Information

Sample Taken Date07/09/2024 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2024
Sample typeVerification A brief description of the sampleAcrow part AB547AS
The quantity of what the sample constitutes19 From where was the sample collectedOther
First name of sampler or witnessed byNikhil Last name of sampler or witnessed byMoon
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6822563796
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAcrow Bridge Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB401-015-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)AB547AS
Washer Mfg. Lot Number(s)AB547AS Bolt SpecificationASTM A325
Bolt Length(s)5.5 Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishASTM A325 HDG
Diameter/Size1" Bolt Mfg. Lot NumberAB547AS
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2024-07-09-9
DIME Test ID: 2024-07-09-9-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2024-08-02

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/26/2024
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AAB547AS1.000086894386.5210.00Wedge Tensileaauvinen

General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 8/2/2024