Summary for Test 2024-07-09-7-8
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994816 DEA: 010E11U4 EFIS: 0123000069 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-1-31.1/31.6 |
| Award Date | 11/15/2023 |
| Closeout Date | Not set |
| Work Description | STRUCTURAL CONC BRIDGE, TEMP BRIDGE AND BAR REINFORCING STEEL. |
| Location Description | MENDOCINO COUNTY NEAR ELK FROM 0.2 MILE SOUTH OF ELK CREEK BRIDGE TO 0.2 MILE NORTH OF ELK CREEK BRIDGE |
| QA Service Level | 1 (Verified on 05/22/2023) |
Sample Information
| Sample Taken Date | 07/09/2024 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/15/2024 | Sample type | Verification |
| A brief description of the sample | Acrow part AB548A | The quantity of what the sample constitutes | 19 |
| From where was the sample collected | Other | First name of sampler or witnessed by | Nikhil |
| Last name of sampler or witnessed by | Moon | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 6822563796 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Acrow Bridge | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B401-013-24 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | AB548A | |
| Washer Mfg. Lot Number(s) | AB548A | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 4 | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | ASTM A325 HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | AB548A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2024-07-09-7
DIME Test ID: 2024-07-09-7-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-08-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 07/26/2024
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 98535 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/2/2024 ✔