Summary for Test 2024-07-21-13-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 995055
DEA: 024H0504
EFIS: 0218000080
DIST-CO-RTE-PM02-SHA-273,299-18.5/18.7,24.1/30.3
Award Date11/16/2023
Closeout DateNot set
Work DescriptionPLACE RHMA, HMA, MINOR CONCRETE, AND REPLACE AC SURFACING.
Location DescriptionSHASTA COUNTY IN AND NEAR REDDING ON ROUTE 273 FROM 0.5 MILE NORTH OF SULPHUR CREEK BRIDGE TO 0.2 MILE SOUTH OF TWIN VIEW BOULEVARD AND ON ROUTE 299 FROM 0.2 MILE WEST OF HILLTOP DRIVE TO 0.1 MILE EAST OF HOOTENANNY LANE
QA Service Level1 (Verified on 10/09/2023)

Sample Information

Sample Taken Date07/21/2024 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing07/24/2024 Sample typeProduction Start-Up
A brief description of the samplePSU The quantity of what the sample constitutes2 CANS
From where was the sample collectedSource First name of sampler or witnessed byC
Last name of sampler or witnessed byB Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVELERO BENCIA
Transportation Laboratory (TL) Number858503 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplierValero Benicia
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2024-07-21-13
DIME Test ID: 2024-07-21-13-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2024-07-26

Test Results


Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 07/25/2024
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 60 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 60 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 59 mm
Resilience 1: 40 %
Resilience 2: 40 %
Resilience 3: 41 %
Average Resilience: 40 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): RESILIENCE

Test was verified on 7/26/2024 ✔