Summary for Test 2024-07-09-110-2
Test performed: AASHTO T308-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
| Project Identifiers | Project ID: 994911 DEA: 101G4204 EFIS: 1017000013 |
|---|---|
| DIST-CO-RTE-PM | 10-STA-132-27.1/28.1 |
| Award Date | 03/28/2023 |
| Closeout Date | 04/22/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/27/2023) |
Sample Information
| Sample Taken Date | 07/09/2024 | Sample Unique Key | 110 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/19/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-A |
| The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Timothy | Last name of sampler or witnessed by | Trefz |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | 24-H-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Teichert - Santa Fe Winton | Transportation Laboratory (TL) Number | 1G42101 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 24J002 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-07-09-110
DIME Test ID: 2024-07-09-110-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-25
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 07/23/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2362.8 g
Mass Loss: 120.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.48 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.51 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/25/2024 ✔
Warning: The test results shown on this page have been superseded and are invalid.