Summary for Test 2024-06-03-114-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date06/03/2024 Sample Unique Key114
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2024
Sample typeQuality Assurance A brief description of the sampleJPCP-RSC Beams
The quantity of what the sample constitutes10 cy From where was the sample collectedJob Site
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byArroyo
Title of sampler Telephone number of sampler
Laboratory sample identification24-1315 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI-JCPC
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-06-03-114
DIME Test ID: 2024-06-03-114-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-07-24

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Rigoberto Arroyo
Date of test: 06/13/2024
Identification number: 24-1315
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8091 lb
Maximum load applied 2: 7812 lb
Maximum load applied 3: 8175 lb
Curing history and apparent moisture condition of the specimen: moist
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen, including numbers of beams discarded during test: n/a
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 680 psi
Modulus of rupture 2: 680 psi
Modulus of rupture 3: 720 psi
Modulus of rupture average: 690 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/24/2024