Summary for Test 2017-06-29-22-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209141 DEA: 07215954 EFIS: 0700001835 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-0.0/7.6 |
Award Date | 04/24/2014 |
Closeout Date | 07/14/2022 |
Work Description | WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES |
Location Description | LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605 |
QA Service Level | 1 (Verified on 06/02/2014) |
Sample Information
Sample Taken Date | 06/29/2017 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2017 |
Sample type | Quality Assurance | A brief description of the sample | Barsplice Griptwist coupler, Zap screwlok type 2 CPLR |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Delira |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | BarSplice Gerdau | Transportation Laboratory (TL) Number | C526284 C526283 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #11 | Coupler Model | Grip Twist Zap Screwlok Couplers |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A165149, A171480, A170529, A171696 | Rebar Heat Number(s) | 65026295 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-06-29-22
DIME Test ID: 2017-06-29-22-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-07-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/18/2017
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 zap | #11/36mm | 1.56 | 0 | 152478 | 97742 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/18/2017 ✔