Summary for Test 2024-07-15-55-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 995145 DEA: 081P6804 EFIS: 0824000077 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-62-3.34/6.5 |
| Award Date | 08/28/2023 |
| Closeout Date | 11/20/2025 |
| Work Description | Remove Debris, Restore Undermined Roadway, Repair Damaged Bridge Piers) |
| Location Description | 3B08-Riv,SBd-62-R3.34/R6.5, 0.0/R2.64 4BOn HWY 62 in Riv & SBd Counties in Morongo Valley Fr 3.2 Mi W/o Indian Canyon Dr to 0.5 Mi W/o Big Morongo Canyon Rd 5B |
| QA Service Level | 1 (Verified on 09/11/2023) |
Sample Information
| Sample Taken Date | 07/15/2024 | Sample Unique Key | 55 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/19/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Barsplice Zap Screwlok Coupler Type 2 |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Shukki | Last name of sampler or witnessed by | Abouazra |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel |
| Coupler Manufacturer | Bar Splice | Intermediate Assembler or Fabricator | |
| Rebar Size | #6 | Coupler Model | Zap Screwlok Coupler Type 2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A235215, A241492 | Rebar Heat Number(s) | 4137912 |
| Rebar Size 2 | Coupler Unique ID | SL-17-03 |
Test Details
DIME Sample ID: 2024-07-15-55
DIME Test ID: 2024-07-15-55-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-07-24
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/22/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | No. 6/19mm | 1 | 0 | 0.44 | 41554 | 94440 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 7/24/2024 ✔