Summary for Test 2024-07-15-55-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995145
DEA: 081P6804
EFIS: 0824000077
DIST-CO-RTE-PM08-RIV-62-3.34/6.5
Award Date08/28/2023
Closeout Date11/20/2025
Work DescriptionRemove Debris, Restore Undermined Roadway, Repair Damaged Bridge Piers)
Location Description3B08-Riv,SBd-62-R3.34/R6.5, 0.0/R2.64 4BOn HWY 62 in Riv & SBd Counties in Morongo Valley Fr 3.2 Mi W/o Indian Canyon Dr to 0.5 Mi W/o Big Morongo Canyon Rd 5B
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date07/15/2024 Sample Unique Key55
Date that the sample was received by the laboratory/organization performing the testing07/19/2024 Sample typeQuality Assurance
A brief description of the sampleBarsplice Zap Screwlok Coupler Type 2 The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byShukki
Last name of sampler or witnessed byAbouazra Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameJob Site
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Steel
Coupler ManufacturerBar Splice Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelZap Screwlok Coupler Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A235215, A241492 Rebar Heat Number(s)4137912
Rebar Size 2 Coupler Unique IDSL-17-03

Test Details

DIME Sample ID: 2024-07-15-55
DIME Test ID: 2024-07-15-55-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-07-24

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/22/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 6/19mm100.444167194707Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 7/24/2024 ✔