Summary for Test 2024-06-06-126-5
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995054 DEA: 024H0204 EFIS: 0218000069 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-36-20.0/39.7 |
| Award Date | 10/23/2023 |
| Closeout Date | 07/03/2025 |
| Work Description | PLACE RHMA AND HMA, CORRECT SEGMENTS, AND REPLACE AC SURFACING. |
| Location Description | TEHAMA COUNTY NEAR RED BLUFF FROM 0.8 MILE EAST OF SALT CREEK BRIDGE TO BAKER ROAD |
| QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
| Sample Taken Date | 06/06/2024 | Sample Unique Key | 126 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/06/2024 | Sample type | Production Start-Up |
| A brief description of the sample | 16 boxes of Lime Treated 3/4-inch RHMA-G (PG 64-16 CR) | The quantity of what the sample constitutes | Production Start Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Cindy |
| Last name of sampler or witnessed by | Bryant | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D79568 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 876860 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-06-126
DIME Test ID: 2024-06-06-126-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-03-07
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 07/22/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3062.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 5076.6 g
Mass of HMA Sample prior to ignition: 2014.3 g
Mass Loss: 162.5 g
Mass of aggregate remaining after ignition: 1851.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.68 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.24 %
General comments (publicly viewable) (Max 1000 characters): Pb=7.24%
Test was verified on 3/7/2025 ✔