Summary for Test 2024-06-17-137-1
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 995058 DEA: 081C5704 EFIS: 0812000332 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.4/10.5,14.9/16.0 |
| Award Date | 10/02/2023 |
| Closeout Date | 12/02/2024 |
| Work Description | DRAINAGE IMPROVEMENT, HMA (MISCELLANEOUS AREA), AND EROSION CONTROL. |
| Location Description | RIVERSIDE COUNTY IN TEMECULA AND MURRIETA FROM SOUTH JUNCTION ROUTE 79 TO 0.1 MILE SOUTH OF KALMIA STREET UNDERCROSSING AND IN WILDOMAR FROM 0.1 MILE SOUTH OF BAXTER ROAD OVERCROSSING TO 0.3 MILE SOUTH OF BUNDY CANYON ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
| Sample Taken Date | 06/17/2024 | Sample Unique Key | 137 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/17/2024 |
| Sample type | Acceptance | A brief description of the sample | Subgrade |
| The quantity of what the sample constitutes | 20.5 kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Gabriel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | I-15 SB, Access Road for MVP C-02 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-06-17-137
DIME Test ID: 2024-06-17-137-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-07-22
Test Results
Is oversize material: No
Input Type: Calculated
Tester's full name: G. Ramirez / R. Jarquin
Date of test: 06/18/2024
In-place wet density: 1.75
Highest adjust wet density: 2.13
% Moisture: no data
Optimum Moisture: no data
Relative compaction: 82
General comments (publicly viewable) (Max 1000 characters): Density Spec 90%
Test was verified on 7/22/2024 ✔