Summary for Test 2024-06-07-30-4

Test performed: ASTM D2369-Jul10

Project Information

Project IdentifiersProject ID: 994835
DEA: 032J9104
EFIS: 0322000136
DIST-CO-RTE-PM03-NEV-80-25.5/27.3
Award Date04/12/2024
Closeout Date06/02/2025
Work DescriptionPOLYESTER CONC, REPLACE JOINT SEAL (ASPHALT RUBBER), CONCRETE BARRIER.
Location DescriptionNEVADA COUNTY NEAR FLORISTON FROM 1.9 MILES EAST OF HINTON ROAD TO TRUCKEE RIVER BRIDGE
QA Service Level1 (Verified on 05/22/2023)

Sample Information

Sample Taken Date06/07/2024 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing06/10/2024 Sample typeQuality Control
A brief description of the sample1 gallon can / 9800 RESIN The quantity of what the sample constitutes2 tankers
From where was the sample collectedSource First name of sampler or witnessed byGILBERTO
Last name of sampler or witnessed byGONZALEZ Title of samplerQuality Control Manager
Telephone number of sampler17076245467 Laboratory sample identification000072KBP
Linked DIME Sample ID000072KBP The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ4E00764
Batch NumberAZ4E00764 Mix numberAZ4E00764

Test Details

DIME Sample ID: 2024-06-07-30
DIME Test ID: 2024-06-07-30-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Test Release Date: 2024-07-23

Test Results


Input Type: Calculated
Tester's full name: Mariano Pontillas
Date of test: 06/27/2024
Mean of two volatile content determination: 42.78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/23/2024 ✔