Summary for Test 2024-06-25-82-5
Test performed: CTM 551-August 2012Project Information
| Project Identifiers | Project ID: 213457 DEA: 11430434 EFIS: 1118000197 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-8-12.9/14.6,14.9 |
| Award Date | 07/16/2022 |
| Closeout Date | 08/21/2025 |
| Work Description | HMA, STRUCTURAL BRIDGE, POLYESTER CONC OVERLAY, JPCP, & CONC BARRIER. |
| Location Description | SAN DIEGO COUNTY IN LA MESA AND EL CAJON FROM 0.1 MILE WEST OF GROSSMONT BOULEVARD OVERCROSSING TO WEST MAIN STREET OVERCROSSING AND AT MARSHALL AVENUE OVERHEAD |
| QA Service Level | 1 (Verified on 06/22/2018) |
Sample Information
| Sample Taken Date | 06/25/2024 | Sample Unique Key | 82 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2024 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can / PPC 1121 RESIN |
| The quantity of what the sample constitutes | 36 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000084KBP | Linked DIME Sample ID | 000084KBP |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | AZ4F00954T |
|---|---|---|---|
| Batch Number | AZ4F00954T | Mix number | AZ4F00954T |
Test Details
DIME Sample ID: 2024-06-25-82
DIME Test ID: 2024-06-25-82-5
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Test Release Date: 2024-07-23
Test Results
Input Type: Measured
Tester's full name: Gilberto Gonzalez
Date of test: 07/02/2024
Curing history for Sample 1: 24hr
Maximum applied load (P) for Sample 1: 1185.45 lb
Span length for Sample 1: 9 in
Break location for Sample 1: bond
Specimen defects/notes for Sample 1: no data
Surface type for Sample 1: SSD
Modulus of rupture (R) for Sample 1: 592.727 psi
Curing history for Sample 2: 24hr
Maximum applied load (P) for Sample 2: 1136.4 lb
Span length for Sample 2: 9 in
Break location for Sample 2: bond
Specimen defects/notes for Sample 2: no data
Surface type for Sample 2: SSD
Modulus of rupture (R) for Sample 2: 568.2 psi
Curing history for Sample 3: 24hr
Maximum applied load (P) for Sample 3: 1024.23 lb
Span length for Sample 3: 9 in
Break location for Sample 3: bond
Specimen defects/notes for Sample 3: no data
Surface type for Sample 3: SSD
Modulus of rupture (R) for Sample 3: 512.117 psi
General comments (publicly viewable) (Max 1000 characters): Accepted vendor's results
Test was verified on 7/23/2024 ✔