Summary for Test 2024-05-24-66-6

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 995028
DEA: 010H4314
EFIS: 0117000214
DIST-CO-RTE-PM01-HUM-299-R11.0/R11.4
Award Date09/26/2023
Closeout Date09/05/2025
Work DescriptionProject Name: Korbel Wall (Description of Work: CONSTRUCT RETAINING WALL, RECONSTRUCT ROADWAY, & REPLACE CULVERT)
Location DescriptionHUMBOLDT COUNTY ABOUT 6 MILES EAST OF BLUE LAKE FROM NORTH FORK MAD RIVER BRIDGE TO 0.4 MILE EAST OF NORTH FORK MAD RIVER BRIDGE
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date05/24/2024 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/25/2024
Sample typeQuality Assurance A brief description of the samplePCC
The quantity of what the sample constitutes60 CY From where was the sample collectedJob Site
First name of sampler or witnessed byZack Last name of sampler or witnessed byArnold
Title of samplerSI Telephone number of sampler
Laboratory sample identificationC9189 Linked DIME Sample ID
The fabricator/manufacturer/facility nameEureka Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberE400FA
The truck number from where the sample was collected84 The batch plant ticket number from where the sample was collected36025
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedsampled from revolving drum truck into a wheelbarrow Where the material sample would have been placed if not sampledLower Waler
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-24-66
DIME Test ID: 2024-05-24-66-6
Testing Lab: SHN Engineers & Geologists, Incorporated
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-07-18

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dave Gonzales
Date of test: 06/21/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 63260 lb
Maximum load on cylinder 2: 68500 lb
Maximum load on cylinder 3: 64600 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 5210 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/18/2024