Summary for Test 2024-07-03-5-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/03/2024 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/12/2024
Sample typeQuality Assurance A brief description of the sampleRocap Assembly
The quantity of what the sample constitutes148 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler385-452-2398
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc. Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-101-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0179609
Heat Number(s)20815060, 213122, 236018 Nut Mfg. Lot Number(s)36103-213122
Washer Mfg. Lot Number(s)236018-38533 Bolt SpecificationA325
Bolt Length(s)5" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMG
Diameter/Size1-1/2" Bolt Mfg. Lot NumberM5733
Rocap Test Requirement(s) Lubricant Requirements(s)Wax and dye

Test Details

DIME Sample ID: 2024-07-03-5
DIME Test ID: 2024-07-03-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2024-07-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/18/2024
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AM57331.5000185075823.266.00Wedge Tensileaauvinen

General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 7/22/2024