Summary for Test 2024-06-27-2-14
Test performed: ASTM A615-20Project Information
| Project Identifiers | Project ID: 994535 DEA: 010H8404 EFIS: 0118000117 |
|---|---|
| DIST-CO-RTE-PM | 01-LAK-20-2.0/2.8 |
| Award Date | 07/21/2023 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, PLACE HMA-A & RHMA, CONST SOLDIER PILE & RETAINING WALLS. |
| Location Description | LAKE COUNTY ABOUT 6 MILES WEST OF UPPER LAKE FROM 0.6 MILE WEST OF IRVINE AVENUE TO 0.1 MILE EAST OF MID LAKE ROAD |
| QA Service Level | 1 (Verified on 04/25/2023) |
Sample Information
| Sample Taken Date | 06/27/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/28/2024 |
| Sample type | Quality Assurance | A brief description of the sample | #9 GR 80 hot rolled threaded bar |
| The quantity of what the sample constitutes | 2252 pcs | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | Krishnamoorthy |
| Title of sampler | Telephone number of sampler | 9512014921 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor Skyline | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
| Threaded Bar Type | Rebar Size | #9 | |
| Nut Specification for Threaded Bar | ASTM A576 | System Manufacturer | Nucor Skyline |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | 5393880,5395823 |
| Nut Heat Number(s) | 5991, 6349 | Bar Lot Number | |
| Nut Lot Number | Coupler Heat Number(s) | ||
| Coupler Grade |
Test Details
DIME Sample ID: 2024-06-27-2
DIME Test ID: 2024-06-27-2-14
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2024-07-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/16/2024
UTM: 400kip
Temperature: 72 f
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | No.9/29mm | 1 | 116037 | 89978 | 0 | Nut | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Nut
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.
Test was verified on 7/17/2024 ✔