Summary for Test 2023-01-20-43-4
Test performed: ASTM C1064-17Project Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 01/20/2023 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/07/2023 |
| Sample type | Quality Assurance | A brief description of the sample | CIDH Pile 5/7 Mason Bent 2 |
| The quantity of what the sample constitutes | 10.5 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Aaron | Last name of sampler or witnessed by | Bennett |
| Title of sampler | TE Civil | Telephone number of sampler | 5107746279 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Syar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 23-0051 | |
| Structure name | Mason | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT072CR8D |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 271139 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-01-20-43
DIME Test ID: 2023-01-20-43-4
Testing Lab: CT D04 - Fairfield Construction Field Office 59-545
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2024-07-16
Test Results
Input Type: Measured
Tester's full name: Rose Saephan
Date of test: 01/20/2023
Temperature: 60 F
General comments (publicly viewable) (Max 1000 characters): Performed by RMA
Test was verified on 7/16/2024 ✔