Summary for Test 2023-02-03-17-3

Test performed: ASTM C143-20

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date02/03/2023 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/07/2023
Sample typeQuality Assurance A brief description of the sampleRW 5 Wall
The quantity of what the sample constitutes3 samples for 28 day From where was the sample collectedJob Site
First name of sampler or witnessed byMohan Last name of sampler or witnessed byAyadurai
Title of sampler Telephone number of sampler5108676121
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Fairfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameRetaining Wall 5 Wall Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1615759
The truck number from where the sample was collected10077032 The batch plant ticket number from where the sample was collected42448229
Concrete batch plantCemex Fairfield The fabricator/manufacturer designation for the sampleCemex
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledjobsite
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-02-03-17
DIME Test ID: 2023-02-03-17-3
Testing Lab: CT D04 - Fairfield Construction Field Office 59-545
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Test Release Date: 2024-07-16

Test Results


Input Type: Measured
Tester's full name: Rose Saephan
Date of test: 02/03/2023
Slump: 5 inch
General comments (publicly viewable) (Max 1000 characters): Performed by RMA

Test was verified on 7/16/2024