Summary for Test 2024-07-01-41-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 07/01/2024 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/04/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" HMA-A 24% RAP |
| The quantity of what the sample constitutes | 750 tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Leif | Last name of sampler or witnessed by | Ayres |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | 2024-07-01-72 | |
| The fabricator/manufacturer/facility name | Mercer Fraser B | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-12-0002 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | HMA Plant Cold Feed | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2024-07-16: HMA Aggregates (Size 1/2"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP | 1 | 2024-07-01-41-1 |
Test Details
DIME Sample ID: 2024-07-01-41
DIME Test ID: 2024-07-01-41-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-07-16
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 07/03/2024
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 95.1 % | ||||||
| 85 % | ||||||
| 58.3 % | ||||||
| 34.6 % | ||||||
| 21.9 % | ||||||
| 15.5 % | ||||||
| 10.6 % | ||||||
| 6.1 % | ||||||
| 3.5 % | ||||||
General comments (publicly viewable) (Max 1000 characters): 76%
Rap 24%
Test was verified on 7/16/2024 ✔
