Summary for Test 2024-07-08-50-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 19 DEA: 010A7704 EFIS: 0100020390 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-21.0/21.5 |
| Award Date | Not set |
| Closeout Date | 04/09/2013 |
| Work Description | Repair Slipout |
| Location Description | Near Crescent City from Crushing Creek Viaduct to .5 miles of the viaduct |
| QA Service Level | 1 (Verified on 03/07/2011) |
Sample Information
| Sample Taken Date | 07/08/2024 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/09/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Hot mix asphalt in boxes |
| The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
| Title of sampler | QC Manager | Telephone number of sampler | 5102077252 |
| Laboratory sample identification | Rich_24_ 082 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Dutra Materials Richmond | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | L210140WMA |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-07-08-50
DIME Test ID: 2024-07-08-50-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-15
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/09/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3074.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 5068.0 g
Mass of HMA Sample prior to ignition: 1993.6 g
Mass Loss: 125.8 g
Mass of aggregate remaining after ignition: 1867.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 899.6 F
Corrected Asphalt Binder Content: 6.16 %
General comments (publicly viewable) (Max 1000 characters): RAP BURN ONLY
Test was verified on 7/15/2024 ✔