Summary for Test 2024-07-09-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994945
DEA: 081J6304
EFIS: 0818000086
DIST-CO-RTE-PM08-SBD-215-3.6/6.0
Award Date09/22/2023
Closeout Date07/23/2025
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC) AND RHMA.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AND SAN BERNARDINO FROM 0.2 MILE SOUTH OF ROUTE 10/215 SEPARATION TO MILL STREET UNDERCROSSING
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date07/09/2024 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2024
Sample typeAcceptance A brief description of the sample3/4" RHMA-G-SP .5% LAS
The quantity of what the sample constitutes4 boxes of RHMA, 1 qt virgin 64-16, 1 qt blended From where was the sample collectedManufacturer
First name of sampler or witnessed byCesar Last name of sampler or witnessed byGomez
Title of samplerPlant QC Telephone number of sampler
Laboratory sample identification0316G-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number226108M IRW LTR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-07-09-17
DIME Test ID: 2024-07-09-17-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-15

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 07/11/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2158.6 g
Mass Loss: 167.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.41 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.22 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/15/2024