Summary for Test 2024-06-11-107-3
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-50-L0.2/R6.1 |
| Award Date | 06/30/2020 |
| Closeout Date | Not set |
| Work Description | Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC |
| Location Description | FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE |
| QA Service Level | 1 (Verified on 10/23/2019) |
Sample Information
| Sample Taken Date | 06/11/2024 | Sample Unique Key | 107 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/03/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 8 Boxes |
| The quantity of what the sample constitutes | 3/4" RHMA-G | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Chittenden |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Daily 24-082 | Linked DIME Sample ID | 2024-06-11-86 |
| The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 7 |
| Sublot number | 1 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-11-107
DIME Test ID: 2024-06-11-107-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-07-12
Test Results
Specified number of passes at 12.7 mm: 25000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 07/12/2024
Test Temperature: 968 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >25000
Stripping Inflection Point (Wheel B): >25000
Maximum impression at 5000 passes (left wheel): 2.38 mm
Maximum impression at 5000 passes (right wheel): 1.4 mm
Average impression at 5000 passes (left/right avg): 1.89 mm
Maximum impression at 10000 passes (left wheel): 2.89 mm
Maximum impression at 10000 passes (right wheel): 1.74 mm
Average impression at 10000 passes (left/right avg): 2.32 mm
Maximum impression at 15000 passes (left wheel): 3.31 mm
Maximum impression at 15000 passes (right wheel): 1.98 mm
Average impression at 15000 passes (left/right avg): 2.65 mm
Maximum impression at 20000 passes (left wheel): 3.63 mm
Maximum impression at 20000 passes (right wheel): 2.14 mm
Average impression at 20000 passes (left/right avg): 2.89 mm
Maximum impression at 25000 passes (left wheel): 4 mm
Maximum impression at 25000 passes (right wheel): 2.31 mm
Average impression at 25000 passes (left/right avg): 3.16 mm
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/12/2024 ✔