Summary for Test 2024-07-08-26-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994546 DEA: 030H3704 EFIS: 0315000151 |
|---|---|
| DIST-CO-RTE-PM | 03-YUB-65-R0.5/1.8 |
| Award Date | 06/08/2023 |
| Closeout Date | 09/11/2026 |
| Work Description | PLACE HMA, RHMA & CONC CURB/SIDEWALK, INSTALL & MODIFY SIGNAL SYSTEMS. |
| Location Description | YUBA COUNTY NEAR WHEATLAND FROM 0.2 MILE SOUTH OF MAIN STREET TO GRASSHOPPER SLOUGH BRIDGE |
| QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
| Sample Taken Date | 07/08/2024 | Sample Unique Key | 26 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/10/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 2 Boxes | The quantity of what the sample constitutes | 3/4" HMA w/ 15% RAP |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | Daily 24-100 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | KRC Hallwood | |
| Transportation Laboratory (TL) Number | C803756 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 2 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-07-08-26
DIME Test ID: 2024-07-08-26-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-12
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/11/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2208.1 g
Mass Loss: 109.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.47 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.47 %
General comments (publicly viewable) (Max 1000 characters): L1
OBC 4.5
Test was verified on 7/12/2024 ✔