Summary for Test 2024-07-09-51-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994546 DEA: 030H3704 EFIS: 0315000151 |
---|---|
DIST-CO-RTE-PM | 03-YUB-65-R0.5/1.8 |
Award Date | 06/08/2023 |
Closeout Date | Not set |
Work Description | PLACE HMA, RHMA & CONC CURB/SIDEWALK, INSTALL & MODIFY SIGNAL SYSTEMS. |
Location Description | YUBA COUNTY NEAR WHEATLAND FROM 0.2 MILE SOUTH OF MAIN STREET TO GRASSHOPPER SLOUGH BRIDGE |
QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
Sample Taken Date | 07/09/2024 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2024 |
Sample type | Quality Assurance | A brief description of the sample | 2 Boxes |
The quantity of what the sample constitutes | 3/4" HMA w/ 15% RAP | From where was the sample collected | Source |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Daily 24-101 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | KRC Hallwood | Transportation Laboratory (TL) Number | C803757 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 3 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-07-09-51
DIME Test ID: 2024-07-09-51-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-12
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/11/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2223.0 g
Mass Loss: 108.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.40 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.48 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 4.5
Test was verified on 7/12/2024 ✔