Summary for Test 2024-07-10-5-3
Test performed: CTM 226-July 2010Project Information
| Project Identifiers | Project ID: 215220 DEA: 07210624 EFIS: 0719000068 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,SBD-71-1.8/R4.7&R0.0/R0.2 |
| Award Date | 02/05/2021 |
| Closeout Date | Not set |
| Work Description | PLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP. |
| Location Description | IN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE. |
| QA Service Level | 1 (Verified on 03/24/2021) |
Sample Information
| Sample Taken Date | 07/10/2024 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2024 |
| Sample type | Acceptance | A brief description of the sample | Washed Concrete Sand |
| The quantity of what the sample constitutes | 55 CY | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Honesto | Last name of sampler or witnessed by | Castillo |
| Title of sampler | MREAS | Telephone number of sampler | 2134537563 |
| Laboratory sample identification | 028C | Linked DIME Sample ID | 2024-07-10-3 & 2024-07-10-4 |
| The fabricator/manufacturer/facility name | Robertsons Ready Mix Concrete-Pomona | Transportation Laboratory (TL) Number | C006806 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0072 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | 5 | A detailed description of where the material sample was collected | Belt Cut at Plant |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | SC675B38 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-07-10-5
DIME Test ID: 2024-07-10-5-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2024-08-06
Test Results
Input Type: Measured
Tester's full name: Honesto Castillo
Date of test: 07/10/2024
Wet weight of the sample: 1124.0000000000 grams
Dry weight of the sample: 1064.0000000000 grams
Weight of water in sample: 60.0000000000 grams
Percent moisture: 5.6 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/6/2024 ✔