Summary for Test 2024-07-01-37-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993253
DEA: 033F0604
EFIS: 0312000052
DIST-CO-RTE-PM03-GLE-162-76.3/78.6
Award Date02/02/2022
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date07/01/2024 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing07/05/2024 Sample typeQuality Assurance
A brief description of the sampleHRC 500 510 Couplers Retest The quantity of what the sample constitutes184
From where was the sample collectedJob Site First name of sampler or witnessed byB
Last name of sampler or witnessed byBaker Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePier 32
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar Manufacturercmc
Coupler ManufacturerHRC Gerdau Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73130162, 73129190 Rebar Heat Number(s)1066920, 1066914, 3125495
Rebar Size 2 Coupler Unique IDTP-17-03

Test Details

DIME Sample ID: 2024-07-01-37
DIME Test ID: 2024-07-01-37-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-07-09

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/09/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 14/43mm302.2522050198001Ultimate - Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ultimate - Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 7/9/2024 ✔