Summary for Test 2024-06-10-43-4
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994946 DEA: 081M5804 EFIS: 0821000143 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10,15,74-var |
| Award Date | 08/24/2023 |
| Closeout Date | 11/04/2024 |
| Work Description | FURNISH POLYESTER CONC OVERLAY, PLACE POLYESTER CONC OVERLAY AND HMA. |
| Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
| Sample Taken Date | 06/10/2024 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA-A-SP R24 0.5%LAS |
| The quantity of what the sample constitutes | 36 BOXES OF HMA, 6 QTS OIL, 3 BAGS OF AGGS | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | HECTOR | Last name of sampler or witnessed by | HECTOR |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0287A-24 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Martin Mariatta-COACHELLA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 43417155 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-10-43
DIME Test ID: 2024-06-10-43-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-09
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 06/13/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2144.0 g
Mass Loss: 108.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.56 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2024 ✔