Summary for Test 2024-06-27-61-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995202
DEA: 033H6104
EFIS: 0318000019
DIST-CO-RTE-PM03-PLA-80-42.7/49.3
Award Date02/15/2024
Closeout DateNot set
Work DescriptionRDWY EXC, HMA, JPCP, ALT PIPELINER, STEEL SOLDIER PILE, MOD LTG SYSTEM
Location DescriptionPLACER COUNTY ABOUT 9.4 MILES NORTH OF COLFAX FROM 0.5 MILE WEST OF MONTE VISTA OVERCROSSING TO 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING
QA Service Level1 (Verified on 11/13/2023)

Sample Information

Sample Taken Date06/27/2024 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/27/2024
Sample typeQuality Assurance A brief description of the sample2 Boxes HMA
The quantity of what the sample constitutes3/4" HMA w/ 25% RAP From where was the sample collectedSource
First name of sampler or witnessed byTim Last name of sampler or witnessed byTim
Title of samplerPlant OC Telephone number of sampler
Laboratory sample identificationDaily 24-064 Linked DIME Sample ID
The fabricator/manufacturer/facility nameDeSilva Gates Marysville Transportation Laboratory (TL) NumberC849939
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number6 HMA Mix Number

Test Details

DIME Sample ID: 2024-06-27-61
DIME Test ID: 2024-06-27-61-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-08

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 06/28/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2242 g
Mass Loss: 124.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.68 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.89 %
General comments (publicly viewable) (Max 1000 characters): Daily 24-064 JMF 24-013

Test was verified on 7/8/2024