Summary for Test 2024-04-15-20-2
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 215697 DEA: 07318204 EFIS: 0715000286 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-Route 1-4.0/4.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | CM/GC Project - Work consists of constructing secant wall and slope restoration |
| Location Description | near Point Mugu State Park 0.4 mile South of Sycamore Canyon Road. |
| QA Service Level | 1 (Verified on 08/26/2021) |
Sample Information
| Sample Taken Date | 04/15/2024 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 1/2" HMA-A-SP 15% RAP |
| The quantity of what the sample constitutes | 16 BOXES OF HMA, 3BAGS OF AGG, 1 BAG OF RAP, 4 QTS OF BINDER | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | GERARDO | Last name of sampler or witnessed by | ZUBIETA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0178A-24 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | All American Asphalt-Irwindale | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 104775 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-04-15-20
DIME Test ID: 2024-04-15-20-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-07-05
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 04/18/2024
| 1 | 2 | 3 | |
|---|---|---|---|
2.9 % | 3.0 % | 3.1 % | |
3.0 % |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/5/2024 ✔