Summary for Test 2017-06-30-8-12
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210828 DEA: 07290704 EFIS: 0712000076 |
---|---|
DIST-CO-RTE-PM | 07-LA-47-0.9/2.0 |
Award Date | 04/06/2016 |
Closeout Date | 06/25/2019 |
Work Description | RESTORE BRIDGE SEISMIC. |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/03/2016) |
Sample Information
Sample Taken Date | 06/30/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/05/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 bolts, Nuts and Washers |
The quantity of what the sample constitutes | 1210 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Leach |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | C and K Johnson | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S3808317 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 3860138, 382765B, | |
Washer Mfg. Lot Number(s) | 0816-325, 0616-263 | Bolt Specification | A325 |
Bolt Length(s) | 6.5 ', 6.25", 4.25",7.5" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8", 1" | Bolt Mfg. Lot Number | 44438, 44463, 379763A, 773472 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-06-30-8
DIME Test ID: 2017-06-30-8-12
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/07/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | S38-083-17 | 7/8\" | 0 | 0 | Slipped out of Grips | Brian |
General comments (publicly viewable) (Max 1000 characters): Slipped out of Grips
Test Graph
Source: Partner Data Point FileTest was verified on 7/11/2017 ✔