Summary for Test 2024-07-02-9-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1000063 DEA: 061F8804 EFIS: 0623000106 |
|---|---|
| DIST-CO-RTE-PM | 06-KIN-41-R39.9/R48.3 |
| Award Date | 04/03/2024 |
| Closeout Date | 04/11/2025 |
| Work Description | COLD PLANE, HMA PAVING, AND INDIVIDUAL CONCRETE SLAB REPLACEMENT. |
| Location Description | KINGS COUNTY AT AND NEAR LEMOORE FROM ROUTE 41/198 SEPARATION TO FRESNO COUNTY LINE |
| QA Service Level | 1 (Verified on 01/29/2024) |
Sample Information
| Sample Taken Date | 07/02/2024 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/02/2024 |
| Sample type | Acceptance | A brief description of the sample | 3/4 hma CF |
| The quantity of what the sample constitutes | 120 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jonathon | Last name of sampler or witnessed by | Chaney |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sierra Pacific - Avenal | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Cold Feed Sampling Chute | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | 1 | |
| Sublot number | 8 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-07-02-9
DIME Test ID: 2024-07-02-9-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-07-03
Test Results
How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 07/03/2024
Clay reading: 5.9
Sand reading: 3.6
Sand Equivalent: 61
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/3/2024 ✔