Summary for Test 2024-06-28-21-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994115
DEA: 010H1914
EFIS: 0117000211
DIST-CO-RTE-PM01-HUM-96-27/27.4
Award Date12/16/2022
Closeout Date07/24/2025
Work DescriptionProject Name: Bluff Creek Wall
Location DescriptionHUMBOLDT COUNTY NEAR WEITCHPEC FROM 0.6 MILE TO 0.2 MILE WEST OF BLUFF CREEK ROAD
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date06/28/2024 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing06/28/2024 Sample typeAcceptance
A brief description of the sample1/2" HMA PG 64-16 The quantity of what the sample constitutes4 Boxes 150 ton
From where was the sample collectedManufacturer First name of sampler or witnessed byGeorge
Last name of sampler or witnessed byThorpe Title of samplerConsultant Tester
Telephone number of sampler(916)2988240 Laboratory sample identification24-102
Linked DIME Sample ID The fabricator/manufacturer/facility nameMercer Fraser Company, Willow Creek Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-06-28-21
DIME Test ID: 2024-06-28-21-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-01

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Travis Sauers
Date of test: 07/01/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1721.5 g
Mass Loss: 94.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.54 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.92 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2024 ✔