Summary for Test 2024-06-18-69-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995013 DEA: 11424804 EFIS: 1116000068 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-54-0/6.4 |
| Award Date | 05/30/2023 |
| Closeout Date | 08/21/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/24/2023) |
Sample Information
| Sample Taken Date | 06/18/2024 | Sample Unique Key | 69 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/20/2024 |
| Sample type | Quality Assurance | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
| Title of sampler | Telephone number of sampler | 8586881440 | |
| Laboratory sample identification | 0303-PSU | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 326120 CROD SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-18-69
DIME Test ID: 2024-06-18-69-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-15
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/01/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4008.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 5551.1 g
Mass of HMA Sample prior to ignition: 1542.6 g
Mass Loss: 103.0 g
Mass of aggregate remaining after ignition: 1439.6 g
Correction Factor (Percent by mass of HMA Specimen): -0.87 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.55 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 7.50 %
Test was verified on 7/15/2024 ✔