Summary for Test 2024-05-30-10-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994115
DEA: 010H1914
EFIS: 0117000211
DIST-CO-RTE-PM01-HUM-96-27/27.4
Award Date12/16/2022
Closeout Date07/24/2025
Work DescriptionProject Name: Bluff Creek Wall
Location DescriptionHUMBOLDT COUNTY NEAR WEITCHPEC FROM 0.6 MILE TO 0.2 MILE WEST OF BLUFF CREEK ROAD
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date05/30/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/31/2024
Sample typeQuality Assurance A brief description of the sampleThree cylinders.
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed bySam Last name of sampler or witnessed byKaplan
Title of samplerASR Telephone number of sampler707-496-0826
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMercer Fraser Willow Crk Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBluff Creek Retaining Wall Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberMFCL1.45SLWCClass1
The truck number from where the sample was collected695 The batch plant ticket number from where the sample was collected002
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedfrom mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-30-10
DIME Test ID: 2024-05-30-10-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-06-27

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 06/27/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 83370 lb
Maximum load on cylinder 2: 84650 lb
Maximum load on cylinder 3: 92500 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.6 in^2
Cross sectional area of cylinder 2: 12.6 in^2
Cross sectional area of cylinder 3: 12.6 in^2
Compressive strength (to nearest 10 psi): 6910 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break 6/27/24

Test was verified on 6/27/2024