Summary for Test 2024-06-11-95-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995155 DEA: 040Q8104 EFIS: 0418000158 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-121-16.0 |
| Award Date | 12/29/2023 |
| Closeout Date | 01/09/2025 |
| Work Description | REPAIR PAVEMENT, REPLACE DRAINAGE SYSTEMS, AND REPLACE GUARDRAIL. |
| Location Description | NAPA COUNTY AT CIRCLE OAKS AT WOODEN VALLEY ROAD |
| QA Service Level | 1 (Verified on 11/06/2023) |
Sample Information
| Sample Taken Date | 06/11/2024 | Sample Unique Key | 95 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/14/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2-INCH HMA Type A and B | The quantity of what the sample constitutes | 2 Boxes LOT 1 SUBLOT 2 |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Nick |
| Last name of sampler or witnessed by | HALL | Title of sampler | Lab Technician |
| Telephone number of sampler | 7072999133 | Laboratory sample identification | Con_24_429 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Vallejo Batch Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 2 | HMA Mix Number | 320914 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-11-95
DIME Test ID: 2024-06-11-95-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 06/14/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1699.7 g
Mass Loss: 149.8 g
Correction Factor (Percent by mass of HMA Specimen): 1.70 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 6.94 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 2
Test was verified on 7/8/2024 ✔