Summary for Test 2024-06-21-3-3

Test performed: ASTM C1064-17

Project Information

Project IdentifiersProject ID: 1000293
DEA: 041X3204
EFIS: 0424000308
DIST-CO-RTE-PM04-SON-1-38.58
Award Date02/22/2024
Closeout DateNot set
Work DescriptionConstruct soldier pile wall, repair east side slide w/ concrete canvass, reconstruct roadway, reconstruct metal beam guardrail, pavement delineation, install structural shotcrete, stain concrete/shotcrete, install cable railing, and install erosions contr
Location DescriptionOcean Cove (North) Emergency Wall at Walsh Landing
QA Service Level1 (Verified on 04/23/2024)

Sample Information

Sample Taken Date06/21/2024 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2024
Sample typeQuality Assurance A brief description of the sampleType II/IV
The quantity of what the sample constitutes31 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRichard Last name of sampler or witnessed byJones
Title of samplerASR Telephone number of sampler15309414305
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRiver Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier20-0116
Structure nameOcean Cove Emergency Wall Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number72203043F
The truck number from where the sample was collected251 The batch plant ticket number from where the sample was collected1651335
Concrete batch plantCanyon Rock Forestville The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampledSoldier Piles 11&13
From Lot No.618547 Bag Lot No.

Test Details

DIME Sample ID: 2024-06-21-3
DIME Test ID: 2024-06-21-3-3
Testing Lab: CT SC - 3672 - Santa Rosa
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2024-06-26

Test Results


Input Type: Measured
Tester's full name: Richard Jones
Date of test: 06/21/2024
Temperature: 75 F
General comments (publicly viewable) (Max 1000 characters): Ambient 70F

Test was verified on 6/26/2024