Summary for Test 2024-06-21-3-3
Test performed: ASTM C1064-17Project Information
| Project Identifiers | Project ID: 1000293 DEA: 041X3204 EFIS: 0424000308 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-1-38.58 |
| Award Date | 02/22/2024 |
| Closeout Date | Not set |
| Work Description | Construct soldier pile wall, repair east side slide w/ concrete canvass, reconstruct roadway, reconstruct metal beam guardrail, pavement delineation, install structural shotcrete, stain concrete/shotcrete, install cable railing, and install erosions contr |
| Location Description | Ocean Cove (North) Emergency Wall at Walsh Landing |
| QA Service Level | 1 (Verified on 04/23/2024) |
Sample Information
| Sample Taken Date | 06/21/2024 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Type II/IV |
| The quantity of what the sample constitutes | 31 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Richard | Last name of sampler or witnessed by | Jones |
| Title of sampler | ASR | Telephone number of sampler | 15309414305 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | River Ready Mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 20-0116 | |
| Structure name | Ocean Cove Emergency Wall | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 72203043F |
|---|---|---|---|
| The truck number from where the sample was collected | 251 | The batch plant ticket number from where the sample was collected | 1651335 |
| Concrete batch plant | Canyon Rock Forestville | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | Soldier Piles 11&13 |
| From Lot No. | 618547 | Bag Lot No. |
Test Details
DIME Sample ID: 2024-06-21-3
DIME Test ID: 2024-06-21-3-3
Testing Lab: CT SC - 3672 - Santa Rosa
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2024-06-26
Test Results
Input Type: Measured
Tester's full name: Richard Jones
Date of test: 06/21/2024
Temperature: 75 F
General comments (publicly viewable) (Max 1000 characters): Ambient 70F