Summary for Test 2024-05-22-114-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 209906
DEA: 033F6504
EFIS: 0313000038
DIST-CO-RTE-PM03-NEV-89-1.2/8.7
Award Date12/16/2014
Closeout Date02/23/2016
Work DescriptionCOLD IN-PLACE RECYCLING AND HOT MIX ASPHALT OVERLAY.
Location DescriptionNEVADA COUNTY IN AND NEAR TRUCKEE FROM 0.7 MILE NORTH OF THE 80/267 JUNCTION TO THE SIERRA COUNTY LINE
QA Service Level1 (Verified on 12/29/2014)

Sample Information

Sample Taken Date05/22/2024 Sample Unique Key114
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2024
Sample typeQuality Assurance A brief description of the sample2 Boxes
The quantity of what the sample constitutes3/4" HMA w/ 25% RAP From where was the sample collectedSource
First name of sampler or witnessed byJesus Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 24-054 Linked DIME Sample ID2024-05-22-112
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number3
Sublot number10 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-05-22-114
DIME Test ID: 2024-05-22-114-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-25

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 06/25/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2141.5 g
Mass Loss: 118.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.46 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.05 %
General comments (publicly viewable) (Max 1000 characters): Daily 24-054 JMF 23-008

Test was verified on 6/25/2024