Summary for Test 2024-05-13-2-3

Test performed: ASTM A615-20

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date05/13/2024 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing06/19/2024 Sample typeQuality Assurance
A brief description of the sampleASTM A108 Grade 80 Nuts The quantity of what the sample constitutes1000
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerAssociate Steel Inspector
Telephone number of sampler707-342-8602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Skyline
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-069-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade80
Threaded Bar TypeDeformed Rebar Size#8
Nut Specification for Threaded BarASTM A108 System ManufacturerNucor Skyline
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)na
Nut Heat Number(s)5393688 5395822 Bar Lot NumberNA
Nut Lot Number6173 6402 Coupler Heat Number(s)NA
Coupler GradeNA

Test Details

DIME Sample ID: 2024-05-13-2
DIME Test ID: 2024-05-13-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2024-06-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 06/24/2024
UTM: 400kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1No.8/25mm0.79103168804990Nutaauvinen

General comments (publicly viewable) (Max 1000 characters): Nut
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 6/25/2024