Summary for Test 2024-06-21-23-3
Test performed: ASTM C231-17aProject Information
| Project Identifiers | Project ID: 995031 DEA: 023H82U4 EFIS: 0223000011 |
|---|---|
| DIST-CO-RTE-PM | 02-LAS-44-0.0/37.2 |
| Award Date | 10/24/2023 |
| Closeout Date | 07/03/2025 |
| Work Description | REPLACE AC SURFACING, PLACE RHMA, HMA, THERMOPLASTIC TRAFFIC STRIPE. |
| Location Description | LASSEN COUNTY ABOUT 9 MILES EAST OF OLD STATION FROM SHASTA COUNTY LINE TO ROUTE 36 |
| QA Service Level | 1 (Verified on 08/10/2023) |
Sample Information
| Sample Taken Date | 06/21/2024 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/21/2024 | Sample type | Quality Control |
| A brief description of the sample | 12 4x8 concrete cylinders | The quantity of what the sample constitutes | 10.5 cyds |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Donald |
| Last name of sampler or witnessed by | Juneman | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Precast Unlimited | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | C85A4D1 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1600 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-06-21-23
DIME Test ID: 2024-06-21-23-3
Testing Lab: Precast Unlimited Inc.
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2024-06-26
Test Results
Is wet sieving required?: No
Input Type: Calculated
Tester's full name: Donald Juneman
Date of test: 06/21/2024
Air content: 1.3 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/26/2024 ✔