Summary for Test 2024-06-21-19-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 995260
DEA: 061G0504
EFIS: 0623000195
DIST-CO-RTE-PM06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0
Award Date03/29/2023
Closeout DateNot set
Work DescriptionRoutes 180, 245 Emergency Slip Out Repair
Location DescriptionNot set
QA Service Level1 (Verified on 10/20/2023)

Sample Information

Sample Taken Date06/21/2024 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing06/21/2024 Sample typeQuality Assurance
A brief description of the sample1x4, 3/8, sand The quantity of what the sample constitutes0-300yd
From where was the sample collectedManufacturer First name of sampler or witnessed byNoah
Last name of sampler or witnessed byHunt Title of samplerSenior Materials Tester
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameOutback Fresno
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-06-21-19
DIME Test ID: 2024-06-21-19-4
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-06-24

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 06/21/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.3
Sand reading (test 1): 4.3
Sand equivalent (test 1): 82
Sand equivalent before temperature correction: 82
Sand equivalent after temperature correction: 82
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/24/2024 ✔