Summary for Test 2024-06-18-41-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 995059 DEA: 081G6404 EFIS: 0816000046 |
---|---|
DIST-CO-RTE-PM | 08-SBD-395-R4.0/49.0 |
Award Date | 10/25/2023 |
Closeout Date | Not set |
Work Description | REPLACE ASPHALT CONCRETE SURFACING, COLD PLANE AC PVMT AND RHMA. |
Location Description | SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM ROUTE 15/395 SEPARATION TO 3.1 MILES NORTH OF ROUTE 58/395 SEPARATION |
QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
Sample Taken Date | 06/18/2024 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/19/2024 |
Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A-SP R15 1% LSM |
The quantity of what the sample constitutes | 4 BOXES OF HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | IDRIS | Last name of sampler or witnessed by | NAJJAR |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0297A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 13 | HMA Mix Number | 300154 LSM |
Test Details
DIME Sample ID: 2024-06-18-41
DIME Test ID: 2024-06-18-41-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-21
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 06/20/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2112.8 g
Mass Loss: 118 g
Correction Factor (Percent by mass of HMA Specimen): 0.49 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2024 ✔