Summary for Test 2024-05-24-24-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 995260 DEA: 061G0504 EFIS: 0623000195 |
---|---|
DIST-CO-RTE-PM | 06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0 |
Award Date | 03/29/2023 |
Closeout Date | Not set |
Work Description | Routes 180, 245 Emergency Slip Out Repair |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/20/2023) |
Sample Information
Sample Taken Date | 05/24/2024 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2024 |
Sample type | Verification | A brief description of the sample | PCC cylinders |
The quantity of what the sample constitutes | 104.5 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Sok | Last name of sampler or witnessed by | Thun |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | 5595199703 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Outback Materials, Fresno | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Concrete Barrier Slab |
Material Information
Material Type | Concrete | The concrete mix design number | 72T1X39 |
---|---|---|---|
The truck number from where the sample was collected | 111 | The batch plant ticket number from where the sample was collected | 160474 |
Concrete batch plant | Outback Materials | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Barrier Slab at Wall 1 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-05-24-24
DIME Test ID: 2024-05-24-24-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-06-21
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 06/21/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 72870 lb
Maximum load on cylinder 2: 73440 lb
Maximum load on cylinder 3: 69810 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5797.1 psi
Compressive strength of cylinder 2: 5842.5 psi
Compressive strength of cylinder 3: 5553.7 psi
Compressive strength (to nearest 10 psi): 5730 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2024 ✔