Summary for Test 2024-05-31-25-4

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/31/2024 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing06/04/2024 Sample typeVerification
A brief description of the sampleJMF 3/4" HMA-A-SP R15, 0.75% LAS The quantity of what the sample constitutes4 Bags of Coldfeed Agg. 2 Bags of Rap
From where was the sample collectedManufacturer First name of sampler or witnessed byJesse/ R
Last name of sampler or witnessed byGomez/Balan Title of sampler
Telephone number of sampler Laboratory sample identification0273A-24
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials- Corona
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-31-25
DIME Test ID: 2024-05-31-25-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2024-07-09

Test Results


Input Type: Measured
Tester's full name: Robert Guillen
Date of test: 06/17/2024
Grading designation: B
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4605 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3836 grams
Percent loss after 100 revolutions: 8 %
Percent loss after 500 revolutions: 23 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/9/2024