Summary for Test 2024-06-13-75-1

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 995221
DEA: 024H0004
EFIS: 0218000067
DIST-CO-RTE-PM02-SIS-97,161-45.0/54.1,0.0/0.8
Award Date02/23/2024
Closeout DateNot set
Work DescriptionHOT MIX ASPHALT, PAVEMENT DELINEATION, & ELECTRICAL WORK.
Location DescriptionSISKIYOU COUNTY IN AND NEAR DORRIS ON ROUTE 97 FROM 0.3 MILE SOUTH OF SAMS NECK ROAD TO OREGON STATE LINE AND ON ROUTE 161 FROM ROUTE 97 TO 0.6 MILE EAST OF INDIAN TOM LAKE ROAD
QA Service Level1 (Verified on 11/27/2023)

Sample Information

Sample Taken Date06/13/2024 Sample Unique Key75
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/19/2024
Sample typeVerification A brief description of the sample2 cans
The quantity of what the sample constitutes2 cans for chip seal/seal coats From where was the sample collectedSource
First name of sampler or witnessed byC. Last name of sampler or witnessed byBryant
Title of samplerTET Telephone number of sampler
Laboratory sample identificationPG641612224KF40 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina - Klamath Falls, OR Transportation Laboratory (TL) NumberC858496
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt (Klamath Falls Plant) - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-06-13-75
DIME Test ID: 2024-06-13-75-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-06-26

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 06/20/2024
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.139 kPa
Phase Angle (δ) (for the 10 cycles): 84.0 degree
Complex Modulus (G*) (for the 10 measurements): 1.153 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.16 kPa
General comments (publicly viewable) (Max 1000 characters): Original

Test was verified on 6/26/2024