Summary for Test 2024-05-21-112-14

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000030
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Award Date10/22/2021
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
QA Service Level1 (Verified on 05/03/2019)

Sample Information

Sample Taken Date05/21/2024 Sample Unique Key112
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/12/2024
Sample typeAcceptance A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byJared Last name of sampler or witnessed bykuplian
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTank at Plant Transportation Laboratory (TL) NumberC728426
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-05-21-112
DIME Test ID: 2024-05-21-112-14
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-06-19

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 06/18/2024
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 41.187 kPa
Phase Angle (δ) (for the 10 cycles): 62.5 degree
Complex Modulus (G*) (for the 10 measurements): 4098.078 kPa
Test Temperature (Specimen 1): 37.0 C
(G*) x sin(δ)=: 3635 kPa
General comments (publicly viewable) (Max 1000 characters): PAV +3

Test was verified on 6/19/2024