Summary for Test 2024-05-23-83-2

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 994191
DEA: 081G8304
EFIS: 0816000079
DIST-CO-RTE-PM08-SBD-40-R100.8/R101.8
Award Date02/07/2023
Closeout Date08/29/2025
Work DescriptionHMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW.
Location DescriptionSAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE
QA Service Level1 (Verified on 03/30/2023)

Sample Information

Sample Taken Date05/23/2024 Sample Unique Key83
Date that the sample was received by the laboratory/organization performing the testing05/29/2024 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byFERNANDO
Last name of sampler or witnessed byCarranza Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-05-23-83
DIME Test ID: 2024-05-23-83-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2024-07-24

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 06/17/2024
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 170.723 grams
Mass of empty container #2: 171.533 grams
Mass of container #1 before test (m1i): 205.532 grams
Mass of container #2 before test (m2i): 207.026 grams
Mass of container #1 after test (m1f): 205.523 grams
Mass of container #2 after test (m2f): 207.018 grams
Average mass change: -0.024 percent
General comments (publicly viewable) (Max 1000 characters): - 0.024 + 0.006 = - 0.018

Test was verified on 7/24/2024 ✔